SPECIFICATION 210/216 REGAL GAS CHLORINATOR
REGAL GAS CHLORINATOR SPECIFICATION 210/216 FEATURES The REGAL Model 210 incorporates the very best available materials with the latest chlorine gas flow meter panel with rate valve, & one (1) ejector/check valve assembly. ... Doc Viewer
Detect chlorine gas More Efficiently And Safely - Dräger USA
››The problem with chlorine gas is that it quickly gets caught on device surfaces, on the diaphragm of a gas detector for example, on the bump test adapter or in the valves of a calibration station‹‹, ex- ... Fetch This Document
Fixed Gas Detectors | Combustible Gas Detection Price | Gas ...
Fixed Gas Detector is widely used in such industries such as petroleum, chemical, natural gas, coal, metallurgy, electric power, municipal administration, telecom,tunnel construction,gas storage ... View Video
How To Handle chlorine gas Safely - Home :: Washington State ...
How to Handle Chlorine Gas Safely Exposure to chlorine is irritating to the eyes, nose, throat, and mucous membranes. At high Allow float in flow meter to drop to zero. Indicator on front of gas feeder should show red indicating no gas. All liquid must be vaporized from the trap. ... Read More
CHLORINE GAS - University Of Guelph
CHLORINE GAS Dr. Youbin Zheng, Siobhan Dunets and Diane Cayanan University of Guelph, Guelph, Ontario, Canada Chlorine gas (Cl 2) is a poisonous, heavy gas that is soluble in water and is the cheapest form of ... Read Content
FCI Thermal Mass ST100L Air/Gas Flow Meter For Municipal ...
The Model ST100L is an in-line, spool piece gas mass flow meter suitable for chlorine gas service and is available with an optional built-in Vortab Flow Conditioner. This inline model is designed specifically for line sizes of 1, 1.5 or 2 inches [DN25, DN40 or DN50], and ... Retrieve Document
Series 6000 Chlorine Pressure Regulator - Hydro Instruments
Series 6000 Chlorine Pressure Regulator 3-Year Limited Warranty Hastelloy-C Inlet Adapters This gas flow meter shall be equipped with a solid Silver rate control valve and solid Silver rate valve sleeve for manual feed rate adjustment. ... Access Document
SERIES 500 GAS CHLORINATORS - Hydro Instruments
Chlorine gas use. HYDRO RM-401 Remote Meter Any number of Hydro Remote Meters may be used in an installation if required. Only the vacuum line is required to the individual ejector which it supplies. Chlo-rine gas can then be precisely metered at ... Access Document
Chlorine - US EPA
Physical Properties Chlorine is a greenish-yellow gas that is slightly soluble in water. (4) Chlorine has a suffocating odor; the odor threshold is 0.31 ppm. ... Fetch Document
Gas Chlorination Systems Series E4000 Instruction Manual
Gas Chlorination Systems Series E4000 Instruction Manual A wall mounted flow meter with manual control valve. 3. The ejector, with nozzle and diffuser, mounts directly to the pipe line, tank, wet well, or to a The chlorine gas is carried from the vacuum regulator to the ejector through ... Read Full Source
Using A Cl2 Sensor To Monitor For ClO2 Using A chlorine ...
Calibration gas to register 5 ppm. On the other hand, if the sensor is being calibrated for the measurement of chlorine dioxide, the readings should be adjusted to register 1.7 ppm. ... Retrieve Document
REGAL GAS CHLORINATOR
The REGAL Gas Chlorinator mounts directly on the cylinder, which is a major safety factor. From the moment chlorine gas leaves the cylinder until it enters the water, it only comes REGAL 7500 Remote Meter Panel used ... Read Content
Chlorine Gas Flow Meter In Chlorinator System
Because chlorine gas is a safety issue for calibration labs and air equivalency calibrations for chlorine are inadequate, FCI provided on-site start-up assistance which included calibration adjustments based on the site’s rotameter measurements. ... Fetch Doc
Product/Specification Bulletin Gas Chlorinator, Series CL-16 ...
A chlorine gas flow meter panel indicates the amount of chlorine being fed and may be located wherever it is safest and most convenient. Chlorine flow rate is manually adjusted and the design permits easy addition of a number of ... Get Doc
AUTOMATIC SWITCHOVER GAS CHLORINATOR
Directly on chlorine gas cylinder valves, one (1) pressure- relief (vent) valve, one (1) chlorine gas flow meter panel with rate valve and one (1) ejector/ check valve assembly. ... View Doc
SPECIFICATION 2101/2107 REGAL GAS CHLORINATOR
High chlorine gas feed rates up to 2000 pounds per 24 hours (40 kg/hr). REGAL Model 2101 Chlorinators are modular in design allowing A chlorine flow meter/rate valve panel is located between these two units and a vacuum lineconnects the three components. ... Read Full Source
LIQUEFIED GAS CONVERSION CHART
LIQUEFIED GAS CONVERSION CHART Product Name Cubic Feet I Pound Pounds I Gallon Cubic Feet I Gallon Acetylene UNINA: 1001 14.70 4.90 72.03 Chlorine CI2 5.1 61 Cyanogen (CN)2 6.8-Cyclopropane C3H6 8.5-Deuterium D2 88.5-Dichlorosilane SiH2CI2 3.5-Dimethylamine C2H7N 7.9- ... Fetch Document
Methane - Wikipedia
Where X is a halogen: fluorine (F), chlorine (Cl), bromine (Br), which is considered to have an energy content of 39 megajoules per cubic meter, Methane gas explosions are responsible for many deadly mining disasters. ... Read Article
Small Water System Chlorination Controls
3 Variable Injection Rate – Variable-rate chlorine injection is more appropriate when flow rates fluctuate significantly, such as when a source has multiple pumps. A digital flow meter controls these chlorination systems by generating digital pulses proportionate to the flow-rate the source or booster pumps produce. ... Access This Document
Carbon Monoxide - Wikipedia
Carbon monoxide (CO) is a colorless, odorless, and tasteless gas that is slightly less dense than air.It is toxic to hemoglobic animals (both invertebrate and vertebrate, including humans) when encountered in concentrations above about 35 ppm, although it is also produced in normal animal metabolism in low quantities, and is thought to have some normal biological functions. ... Read Article
CLM-1 Spec Sheet - SUPERIOR Gas Chlorinators
A chlorine gas flow meter indicates the amount of chlorine being fed. Chlorine flow rate is manually adjusted and the design permits easy addition of a number of automatic flow rate control devices. A high efficiency, water operated ejector produces ... Fetch Full Source
Micro Motion Flowmeters Eliminate The Environmental And ...
Environmental and Process Hazards of Measuring Chlorine Gas RESULTS A chemical processing company measures chlorine gas. In this process, chlorine is batched to a gas phase reactor. A high-value The Micro Motion meter was installed horizontally to ... Document Retrieval